Matrix Switching SystemUser Manual
23
8.0 Communication Protocol/Control Command Code
Communication Protocol: Baud rate 9600bps, no odd or even calibration bit address,
8bit transmission address, 1bit stop address. Please refer to the “Command list.pdf in
the CD-ROM for more related Command Code information.
9.0 Troubleshooting
1. What do I do if the HDMI matrix front panel switching keys are not responding?
Answer: The HDMI matrix front panel keys employ scanning testing and require longer
response time. Press and hold the keys for 2 seconds. This will ensure key
switching will be responsive in operation.
2. What do I do if matrix does not display or color display is abnormal after hot plug?
Answer: Switching of the matrix system goes through the IC chips. If the voltage
difference between the input signal equipment and the matrix equipment is too
large, hot plug could easily cause damage to the IC chips. Please turn off the
power to the system before plugging or unplugging.
3. What do I do if there is a loss of color reproduction, or no video signal output?
Answer: Please check if connectors at both ends of the HDMI signal cable are correctly
connected.
4. What do I do if the serial port (usually refer to the computer serial port) fails to control
the HDMI matrix?
Answer: Check that the communication port set by the control software is correctly
connected to the corresponding serial port of the equipment. Also, check to
see if the computer communication port is in good order.
5. What do I do if the corresponding graphics fail to output during HDMI matrix
switching?
Answer:
(1) Check if there is signal on the input end. If there is no input signal, it could be that the
input connection cable is broken or the connector gets loose. You are advised to
replace the connection cable.
(2) Check if there is signal on the output end. If there is no output signal, it could be that
the cable is broken or the connector gets loose. You are advised to replace the
connection cable.